Climatic test chambers with forced air circulation: KBK-18W, KBK-30W, KBK-65W, KBK-100W, KBK-150WY, KBK-150WX, KBK-200W
Intended for laboratory tests and experiments at temperatures lower than ambient temperature and at higher and specific temperatures as well as 5 to 95% humidity. Forced air circulation reduces the time necessary to achieve the optimum temperature, and to provide an even temperature distribution across the device. The devices are equipped with double autonomous systems as a protection against uncontrolled temperature surges.
- Microprocessor control system;
- Stainless steel chamber;
- Shelves made of wire mesh
- Powder varnished casing;
- Chamber equipped with a dual system-operated protection against accidental temperature increase (charge protection);
- Chamber equipped with an autonomous protection system against exceeding the temperature limit inside the device (apparatus protection);
- Possibility of multi-cycle programming
- Defrosting system
- Temperature adjustment ranging from -5oC to +70oC (LUX only);
- Temperature adjustment ranging from +5oC to +70oC (STANDARD only);
- Single temperature cycle duration programming ranging from:
- 1 min to 999.9 h every minute
- continuous running
- Accuracy of temperature stabilization at the set point
of ± 0.1oC - Accuracy of temperature setting and thermometer reading 0.1 oC
- Humidity setting from 0 to 95%
- Accuracy of humidity reading ± 1%
- Optional delayed start setting
- Sound signalling on completion of each cycle and the entire program;
- Digital temperature measurement;
- Digital humidity measurement;
- Complete information on each program stage completion in the course of chamber operation
- Intelligent control of chamber operation interruptions
in the course of program cycles in case of power loss and recovery; - Connection to PC in order to:
- programme chamber operation parameters
- record the process, tabular presentation of measurement results;
- graphic visualization of the process course;
- optional incubator work preview via INTERNET
- optional SMS about incubator failure sent to mobile phone.
- USB port for data transfer to PC
- Single glass door;
- Stainless steel powder varnished casing
- Additional thermal protection;
- Non-standard capacities of the working chamber;
- Microprocessor control system;
- Stainless steel chamber;
- Shelves made of wire mesh
- Powder varnished casing;
- Chamber equipped with a dual system -operated protection against accidental temperature increase (charge protection);
- Chamber equipped with an autonomous protection system against exceeding the temperature limit inside the device (apparatus protection);
- Possibility of multi-cycle programming
- Defrosting system
- Temperature adjustment ranging from +5oC to +70oC
- Single temperature cycle duration programming ranging from:
- 1 min to 999.9 h every minute
- continuous running - Accuracy of temperature stabilization at the set point of ± 0.1oC
- Accuracy of temperature setting and thermometer reading 0.1 oC
- Humidity setting from 10 to 95%
- Accuracy of humidity reading ± 1%
- Optional delayed start setting
- Sound signalling on completion of each cycle and the entire program;
- Digital temperature measurement
- Digital humidity measurement;
- Complete information on each program stage completion in the course of chamber operation
- Intelligent control of chamber operation interruptions in the course of program cycles in case of power loss and recovery;
- Connection to PC in order to:
- programme chamber operation parameters
- record the process, tabular presentation of measurement results;
- graphic visualization of the process course;
- USB port for data transfer to PC
- Single glass door;
- Stainless steel powder varnished casing
- Additional thermal protection;
- Non-standard capacities of the working chamber;
- Temperature setting with 0.1oC increment ranging from -5oC up to 70oC;
- Perforated shelves or solid shelves made of sheet;
- Internal cooling system.
- Connection to PC in order to:
- optional incubator work preview via INTERNET
- optional SMS about incubator failure sent to mobile phone